UNIT CONVERSIONS
  • Inches = millimeters / 25.4
  • Millimeters = inches * 25.4
  • Feet = meters / 0.3048
  • Meters = feet * 0.3048
  • Centigrade = 0.556 * (Fahrenheit - 32)
  • Fahrenheit = 1.8 * (Centigrade + 32)
  • Pounds = kilograms * 2.205
  • Kilograms = pounds * 0.454
  • Degrees = 180 * radians / PI
  • Radians = PI * degrees /180


POWER CALCULATIONS

  • Power = Voltage * current (Watts = Volts * Amps)
  • Current = Power / Voltage (Amps = Watts / Volts)
  • RMS Volts = 0.707 * Peak Volts RMS Volts = 1.11 * Average Volts


LIGHT OUTPUT CALCULATIONS
  • Lux = candela / distance in meters * distance in meters
  • Foot-candles = candela / distance in feet * distance in feet
  • Foot-candles = Lux / 10.764 = lumens/sq. meter
  • Lumens/sq. ft. * 1 = foot-candles
  • Lumens/sq. ft. * 10.764 = lumens/sq. meter
  • Lumens * 0.07958 = spherical candle power
  • Lux * 0.0929 = foot-candles
  • Lambert * 0.3183 = candles/sq. cm
  • Lambert * 295.720 = candles sq. ft.
  • Lambert * 1 = lumens/sq. cm


LIGHT CALCULATIONS
  • Foot-candles * 10.764 = lumens/sq. meter = lux
  • Lumens/sq. ft. * 1 = foot-candles
  • Lumens/sq. ft. * 10.764 = lumens/sq. meter
  • Lumens * 0.07958 = spherical candle power
  • Lux * 0.0929 = foot-candles
  • Lambert * 0.3183 = candles/sq. cm
  • Lambert * 295.720 = candles sq. ft.
  • Lambert * 1 = lumens/sq. cm


LIGHT BEAM CALCULATIONS
  • Beam diameter = distance * (2 * tan (beam angle / 2))
  • Throw distance = Square root ((horizontal dist. * horizontal dist.) + (vertical dist. * vertical dist.))
  • DC VOLTAGE DROP OF CONDUCTOR (cable) OF L


LENGTH CALCULATIONS
  • V = voltage drop, I = current
  • R = resistance of conductor per 1000 feet
  • L = length of conductor in feet
  • R for 18awg = 6.51, 16awg = 4.09, 14awg = 2.58
  • 12awg = 1.62, 10awg = 1.02, 8awg = 0.64
  • V = I * L * (R / 1000) * 1.004